The Manufacturing Internet Connector (MIC) adds intelligence to machinery where none currently exists. By utilizing a unique combination of digital, analog, and relay I/O ports, MIC can not only monitor counters and sensors, it can send commands to equipment from operators and software. Add communication, control, and convenience to your devices.

I/O CONNECTIONS

  • Relay: 4 outputs
    • Normally open
    • 5A/30VDC 5A/250VAC
  • Digital input: 4 inputs
    • 0-24VDC
  • Counters: 4 counters
    • 50Hz (50% duty cycle
    • 32 bit
  • Analog input: 4 channels
    • 0-5V input range
    • 10-bit resolution
  • USB ports: 4 x USB 2.0

OTHER PORTS

  • HDMI
  • 3.5mm analog audio jack
  • Not accessible
    • Camera serial interface (CSI)
    • Digital serial interface (DSI)
    • 12C

OPERATING SYSTEM

  • Linux (Raspbian Jessie)
  • Software/hardware development environment:
    • Python
    • Python3
    • GCC
  • Whetstone (MWIPS): 711
  • Dhrystone: 2458

NETWORK INTERFACE

  • 10/100 MBPS Ethernet
  • 802.11n Wireless LAN
  • Bluetooth 4.0

POWER

  • 5VDC
  • 2A
  • Micro-USB
  • 0.100" diameter barrel connection

ONBOARD HARDWARE

  • SoC: Broadcom BCM2837
  • CPU: 64-bit, 1.2 GHz quad-core ARM Cortex A53
  • GPU: Broadcom VideoCore IV @ 400MHz
  • Memory: 1 GB LPDDR2-900 SDRAM
  • Storage: MicroSD 8GB

PHYSICAL

  • 4.6875" D x 4.00" W x 1.75" H (11.91 cm D x 10.16 cm W x 4.45 cm H)
  • Operating Temperature: 0-70° C

MIC PROGRAMMING MANUAL

User manual and hardware interface guide for the MIC. *COMING SOON!*

EDAS-2000

The EDAS CE Base System consists of a Power Module and a CPU Module. Up to 12 I/O Modules in any configuration and combination can be attached to the CPU Module. Since each I/O module can offer up to 16 channels, systems with up to 192 channels can be configured. For even larger systems multiple EDAS CE units can be used that communicate with each other through Ethernet. Communication between the CPU and the modules is achieved through an enhanced PC/104 bus. During boot time the hardware configuration and combination of modules is automatically detected.

POWER REQUIREMENTS

  • 1A: 90-260VAC input, 5V, 10A output
  • 2A: 90-260VAC input, +5 and +12VDC accessory power
  • 3A: 90-260VAC input, +5 and +24VDC accessory power
  • 80 character display buffer
  • Display can flash and blink
  • Font supports underscore and block

DIGITAL I/O

  • 8 digital inputs 24VDC
  • 4 digital outputs 24VDC
  • Inputs can be configured as counters or latches
  • Outputs can be configured for pulse or squarewave
  • Used with the EDAS-2002M-1 module

ANALOG INPUT

  • 1A 16/8 SE/Diff channels, 12-bit, Programmable gain (1,10,100), Voltage, Current
  • 2A has 16/8 SE/Diff channels, 200KHz, 12-bit, Programmable gain (1, 10, 100), Voltage, Current
  • 3A has 16/8 SE/Diff channels, 200KHz, 12-bit, Programmable gain (1, 10, 100), Voltage, Current
  • Thermocouple, Built in CJC
  • Used with the EDAS-2003M module

EDAS CE SOFTWARE MANUAL

User manual for the EDAS CE.

EDAS-1001

EDAS-1000E Series Ethernet Data Acquisition Systems are stand-alone data acquisition systems that connect to and communicate over Ethernet (IEEE 802.310Base-T) Local Area Networks(LANs). Using (TCP/IP) they enable you to integrate acquired data with your facility-wide or world-wide network, making the data available for use by other networked resources, or for further processing by personal or company software.

DIGITAL I/O

  • 8 channels (bits) per port (4 programmable for input or output)
  • TTL-compatible (Schmitt Trigger) input levels
  • Input current:
    • Port 0 (high level/low level): 20μA/200μA
    • Port 1 (high level/low level): 5μA/5μA
  • TTL-compatible output levels
  • Output current:
    • Port 0 (source/sink): 15mA/24mA
    • Port 1 (source/sink): 15mA/64mA

COUNTERS

  • General purpose: 24-bit
    • Up to 32 channels
    • Max input frequency (TTL-level input): 250Hz
  • 16-bit high speed
    • Used with the EDAS-2002M-1 module
    • Max input frequency (TTL-level input): 250kHz

SERIAL PORTS

  • RS-232
    • DE-9 connector
    • Serial asynchronous (ASCII) communication
    • Supply voltages (3k ohm load):
      • ±6V TX
      • 16-bit
      • RX active
  • RS-485 (EDAS-1001E-2C)
    • 3-wire screw terminal block connector
    • Serial asynchronous (ASCII) communication
    • Isolation (1 minute): 1600 Vrms

NETWORK INTERFACE

  • Ethernet 10Base-T (RJ45)
  • 8kHz system throughput (unloaded network)

POWER

  • Voltage range (AC or DC): 15 to 28 VAC, 20 to 40 VDC
  • Current requirements* (24VAC, no load/1A load): 200mA/500mA

PHYSICAL

  • 6.00″ D x 5.57″ W x 1.52″ H (15.24 cm D x 14.15 cm W x 3.86 cm H)
  • 0° to 50° C**
  • *The on-board power supply circuit can supply up to 1A @ 5VDC to termination panels through the 50-pin I/O connectors
  • **All specifications are typical at 25° C unless otherwise noted

EDAS 1000 SERIES MANUAL

User Manual for the EDAS-1000 Data Acquisition Systems series.

EDAS-1002

The EDAS-1002E-1A model combines analog I/O and digital I/O data acquisition functions (8 differential or 16 single-ended analog inputs, 2 analog outputs, 16 digital I/O channels and one counter). Like the EDAS-1001E-1A, this unit also contains a built-in processor, ROM-based executive firmware, TCP/IP, an Ethernet interface and an RS-232 port for serial I/O (and for initial network configuration of the unit). The EDAS-1002E-2A model has all the above features and an RS-485 serial port for communication with multiple RS-485 devices.

NETWORK INTERFACE

  • Ethernet 10Base-T (RJ45)
  • 8kHz system throughput (unloaded network

POWER REQUIREMENTS

  • Voltage range (AC or DC): 15 to 28 VAC, 20 to 40 VDC
  • Current requirements* (24VAC, no load/1A load): 350mA/650mA

PHYSICAL

  • 9.00″ D x 5.57″ W x 1.52″ H (22.86 cm D x 14.15 cm W x 3.86 cm H)
  • OEM (board only) versions: 8.50″ D x 5.28″ W x 1.10″ H (21.59 cm D x 13.41 cm W x 2.79 cm H)
  • 0° to 50° C operating temperature range**
  • *The on-board power supply circuit can supply up to 1A @ 5VDC to termination panels through the 50-pin I/O connectors
  • **All specifications are typical to 25° C unless otherwise noted

DIGITAL INPUTS AND OUTPUTS

  • 2 ports, programmable for input or output (8 channels/bits per port)
  • TTL-compatible (Schmitt Trigger) input levels
  • Input current:
    • Port 0 (high level/low level): 20μA/200μA
    • Port 1 (high level/low level): 5μA/5μA
  • TTL-compatible output levels
  • Output current:
    • Port 0 (source/sink): 15mA/24mA
    • Port 1 (source/sink): 15mA/64mA

DIGITAL I/O COUNTERS

  • 24-bit general purpose
    • Up to 16 channels
    • Max input frequency (TTL-level input): 250Hz
  • 16-bit high speed
    • 1 input only channel
    • Max input frequency (TTL-level input): 250kHz

DIGITAL I/O TIMEBASE GENERATOR

  • 1 crystal-based rate generator (32-bit)
  • 125 ns resolution
  • Output frequency range: 0.001 Hz to 1 MHz

DIGITAL I/O SERIAL PORTS

  • RS-232
    • DE-9 connector
    • Serial asynchronous (ASCII) communication
    • Supply voltages (3k ohm load): ±6V TX
  • RS-485 (EDAS-1002E-2A)
    • 3-wire screw terminal block connector
    • Communication
    • Isolation (1 minute): 1600 Vrms

ANALOG OUTPUTS

  • 2 Channels
  • 12-bits (1 part in 4069) resolution
  • Voltage ranges: ±10V
  • Load current: ±5mA

ANALOG INPUTS

  • 16 single-ended channels
  • 8 differential channels
  • 12-bits (1 part in 4069) resolution
  • 16-bits (1 part in 65,536) resolution
  • Voltage ranges:
    • Gain = 1: 0-10V, ±10V
    • Gain = 10: 0-1V, ±1V
    • Gain = 100: 0-0.1V, ±0.1V
  • Overvoltage protection (power on/power off)
    • 12-bit: ±35V/±20V
    • 16-bit: -40V to +55V
  • Sampling Rate:
    • 12-bit:
      • Gain = 1: 100kHz
      • Gain = 10 or 100:
    • 16-bit:
      • Gain = 1: 40kHz
      • Gain = 10 or 100: 2.5kHz
  • Gain Accuracy
    • 12-bit:
      • Gain = 1: ±0.012%
      • Gain = 10 or 100: ±0.05% typical, ±0.25% max
    • 16-bit:
      • Gain = 1: ±0.009%
      • Gain = 10 or 100: ±0.05% typical, ±0.25% max
  • Offset Voltage (referenced to input):
    • 12-bit: 3mV
    • 16-bit: 150μV
  • Input Impedance:
    • 12-bit:
      • Differential mode: 10**9 ohms/50pF
      • Common mode:
    • 16-bit:
      • Differential mode: 10**10 ohms/100pF
      • Common mode: 10**10ohms/110pF
  • Common mode range (Vcm = Vrange - (Vdiff * Gain)/2): ±10V (DC + Peak AC) min
  • Rejection
    • 12-bit:
      • Gain = 1: -85dB
      • Gain ≥ 10: -90dB
    • 16-bit:
      • 60Hz, 100 ohm imbalance: -90dB
  • Noise:
    • 12-bit:
      • RMS (all gains): 1.0 LSB
    • 16-bit:
      • Gain = 1: 2LSB RMS
      • Gain = 10: 3LSB RMS
      • Gain = 100: 6LSB RMS
  • Linearity Error: (full scale range)
    • 12-bit: 0.024%
    • 16-bit: 0.005% (3.0 LSB)

EDAS 1000 SERIES MANUAL

User Manual for the EDAS-1000 Data Acquisition Systems series.

EDAS-1025

The EDAS-1025 Serial EDAS systems can allow any RS-232 device, including PLC’s, controllers, instruments, scales, gauges, smart sensors, machines, printers, terminals and scanners, to communicate with computers located anywhere on an Ethernet network. Each EDAS-1025 Serial EDAS provides 2 or 4 RS-232 serial ports.

Use this system to allow any RS-232 device, including PLC’s, controllers, instruments, scales, gauges, smart sensors, machines, printers, terminals and scanners, to communicate with computers located anywhere on an Ethernet network. Monitor and Control all types of RS-232 Devices remotely, at any distance, via your existing network. Provides full 2-way communication with each device, from one or more computers – even simultaneously.

SERIAL PORTS

  • RS-232: 2 or 4 ports
  • DE-9 connector
  • ASCII, binary communication
  • Supply voltage (3k ohm load) ±6V TX, RTS active

NETWORK INTERFACE

  • Ethernet 10Base-T
  • RJ45 connector
  • Buffer RAM: 4kB
  • EEPROM: 1-24 bits
  • Controller: SMC91C94

RESET CONTROLLER

  • Type: MAX809 (or equivalent)
  • 4.4V threshold voltage
  • Range (-40° to +85° C*): 4.25V to 4.5V/140msec to 560msec
  • Reset active time-out period: 240msec

POWER

  • Voltage range (AC or DC): 15 to 28 VAC, 20 to 40 VDC
  • OEM (board only) versions (DC): 5VDC
  • Current Requirements
    • 24VAC, no load/1A load: 125mA typical
    • 24VAC: 250mA typical
  • TTL-compatible output levels
  • Output current:
    • Port 0 (source/sink): 15mA/24mA
    • Port 1 (source/sink): 15mA/64mA

PHYSICAL

  • Base material: aluminum
  • Cover material: vinyl-clad steel
  • Bezel material: nickel-coated molded ABS plastic
  • Size: 5.125″ D x 7.70″ W x 1.70″ H (13.0 cm D x 19.56 cm W x 4.32 cm H)
  • OEM (board only) version size: 4.50″ D x 7.00″ W x 1.10″ H (11.43 cm D x 17.78 cm W x 2.79 cm H)
  • 0° to 50° C** operating temperature range
  • *The on-board power supply circuit can supply up to 1A @ 5VDC to termination panels through the 50-pin I/O connectors
  • **All specifications are typical at 25° C unless otherwise noted

EDAS 1025E MANUAL

User Manual for the EDAS-1025E terminal.

 

EDAS-1027

The EDAS-1027 Industrial EDAS systems are housed in NEMA-12 rated enclosures for use in harsh environments. It provides 16 digital I/O channels, which are individually configurable as inputs or outputs. With the use of isolated signal conditioning modules, 10 to 280 Volt I/O ranges are supported. Any signal conditioning or isolation modules used are within the enclosure.

DIGITAL I/O

  • 8 channels (bits) per port (4 programmable for input or output)
  • TTL-compatible (Schmitt Trigger) input levels
  • Input current:
    • Port 0 (high level/low level): 20μA/200μA
    • Port 1 (high level/low level): 5μA/5μA
  • TTL-compatible output levels
  • Output current:
    • Port 0 (source/sink): 15mA/24mA
    • Port 1 (source/sink): 15mA/64mA

COUNTERS

  • General purpose: 24-bit
    • Up to 32 channels
    • Max input frequency (TTL-level input): 250Hz
  • 16-bit high speed
    • Used with the EDAS-2002M-1 module
    • Max input frequency (TTL-level input): 250kHz

SERIAL PORTS

  • RS-232
    • DE-9 connector
    • Serial asynchronous (ASCII) communication
    • Supply voltages (3k ohm load):
      • ±6V TX
      • 16-bit
      • RX active
  • RS-485 (EDAS-1001E-2C)
    • 3-wire screw terminal block connector
    • Serial asynchronous (ASCII) communication
    • Isolation (1 minute): 1600 Vrms

NETWORK INTERFACE

  • Ethernet 10Base-T (RJ45)
  • 8kHz system throughput (unloaded network)

POWER

  • Voltage range (AC or DC): 15 to 28 VAC, 20 to 40 VDC
  • Current requirements* (24VAC, no load/1A load): 200mA/500mA

PHYSICAL

  • 6.00″ D x 5.57″ W x 1.52″ H (15.24 cm D x 14.15 cm W x 3.86 cm H)
  • 0° to 50° C**
  • *The on-board power supply circuit can supply up to 1A @ 5VDC to termination panels through the 50-pin I/O connectors
  • **All specifications are typical at 25° C unless otherwise noted

EDAS 1000 SERIES MANUAL

User Manual for the EDAS-1000 Data Acquisition Systems series.

EDAS-1031

The EDAS-1031E is a high-resolution member of the EDAS 1000 Series. The model combines 16-bit resolution analog input, 12-bit analog output and digital I/O data acquisition functions (8 differential or 16 single-ended analog inputs, 2 analog outputs, 16 digital I/O channels and one counter). The EDAS-1031E-1A model contains a built-in processor, ROM-based executive firmware, TCP/IP, an Ethernet interface and an RS-232 port for serial I/O (and for initial network configuration of the unit).

The EDAS-1031E-2A model has all the above features and an RS-485 serial port for communication with multiple RS-485 devices. EDAS-1031E units also feature Ethernet communication diagnostic LEDs located at the back panel of each unit (these LEDs are located inside the case on other EDAS models).

NETWORK INTERFACE

  • Ethernet 10Base-T (RJ45)
  • 8kHz system throughput (unloaded network

POWER REQUIREMENTS

  • Voltage range (AC or DC): 15 to 28 VAC, 20 to 40 VDC
  • Current requirements* (24VAC, no load/1A load): 350mA/650mA

PHYSICAL

  • 9.00″ D x 5.57″ W x 1.52″ H (22.86 cm D x 14.15 cm W x 3.86 cm H)
  • OEM (board only) versions: 8.50″ D x 5.28″ W x 1.10″ H (21.59 cm D x 13.41 cm W x 2.79 cm H)
  • 0° to 50° C operating temperature range**
  • *The on-board power supply circuit can supply up to 1A @ 5VDC to termination panels through the 50-pin I/O connectors
  • **All specifications are typical to 25° C unless otherwise noted

DIGITAL INPUTS AND OUTPUTS

  • 2 ports, programmable for input or output (8 channels/bits per port)
  • TTL-compatible (Schmitt Trigger) input levels
  • Input current:
    • Port 0 (high level/low level): 20μA/200μA
    • Port 1 (high level/low level): 5μA/5μA
  • TTL-compatible output levels
  • Output current:
    • Port 0 (source/sink): 15mA/24mA
    • Port 1 (source/sink): 15mA/64mA

DIGITAL I/O COUNTERS

  • 24-bit general purpose
    • Up to 16 channels
    • Max input frequency (TTL-level input): 250Hz
  • 16-bit high speed
    • 1 input only channel
    • Max input frequency (TTL-level input): 250kHz

DIGITAL I/O TIMEBASE GENERATOR

  • 1 crystal-based rate generator (32-bit)
  • 125 ns resolution
  • Output frequency range: 0.001 Hz to 1 MHz

DIGITAL I/O SERIAL PORTS

  • RS-232
    • DE-9 connector
    • Serial asynchronous (ASCII) communication
    • Supply voltages (3k ohm load): ±6V TX
  • RS-485 (EDAS-1002E-2A)
    • 3-wire screw terminal block connector
    • Communication
    • Isolation (1 minute): 1600 Vrms

ANALOG OUTPUTS

  • 2 Channels
  • 12-bits (1 part in 4069) resolution
  • Voltage ranges: ±10V
  • Load current: ±5mA

ANALOG INPUTS

  • 16 single-ended channels
  • 8 differential channels
  • 12-bits (1 part in 4069) resolution
  • 16-bits (1 part in 65,536) resolution
  • Voltage ranges:
    • Gain = 1: 0-10V, ±10V
    • Gain = 10: 0-1V, ±1V
    • Gain = 100: 0-0.1V, ±0.1V
  • Overvoltage protection (power on/power off)
    • 12-bit: ±35V/±20V
    • 16-bit: -40V to +55V
  • Sampling Rate:
    • 12-bit:
      • Gain = 1: 100kHz
      • Gain = 10 or 100:
    • 16-bit:
      • Gain = 1: 40kHz
      • Gain = 10 or 100: 2.5kHz
  • Gain Accuracy
    • 12-bit:
      • Gain = 1: ±0.012%
      • Gain = 10 or 100: ±0.05% typical, ±0.25% max
    • 16-bit:
      • Gain = 1: ±0.009%
      • Gain = 10 or 100: ±0.05% typical, ±0.25% max
  • Offset Voltage (referenced to input):
    • 12-bit: 3mV
    • 16-bit: 150μV
  • Input Impedance:
    • 12-bit:
      • Differential mode: 10**9 ohms/50pF
      • Common mode:
    • 16-bit:
      • Differential mode: 10**10 ohms/100pF
      • Common mode: 10**10ohms/110pF
  • Common mode range (Vcm = Vrange - (Vdiff * Gain)/2): ±10V (DC + Peak AC) min
  • Rejection
    • 12-bit:
      • Gain = 1: -85dB
      • Gain ≥ 10: -90dB
    • 16-bit:
      • 60Hz, 100 ohm imbalance: -90dB
  • Noise:
    • 12-bit:
      • RMS (all gains): 1.0 LSB
    • 16-bit:
      • Gain = 1: 2LSB RMS
      • Gain = 10: 3LSB RMS
      • Gain = 100: 6LSB RMS
  • Linearity Error: (full scale range)
    • 12-bit: 0.024%
    • 16-bit: 0.005% (3.0 LSB)

EDAS 1000 SERIES MANUAL

User Manual for the EDAS-1000 Data Acquisition Systems series.

Hardware Solutions

See the rest of our Data Collection Hardware solutions

Ethernet Time Clocks

Operator Interface Terminals

Ethernet Data Collection Terminals

Ethernet Data Acquisition Systems